Poor earthing rarely announces itself. The lights stay on and the machines keep running, until a fault happens and the protection does not trip, or a person touches a live metal body, or a storm takes out the electronics. Most failures trace back to a handful of avoidable mistakes. Here are the ones that turn up most often.
What happens when earthing is not proper
- Metal bodies of equipment can become live during a fault, creating a shock risk.
- MCBs and RCDs may not trip, or trip late, because the fault current has no good path.
- Surges and lightning find their way into wiring and electronics instead of into the ground.
- Equipment suffers nuisance tripping, resets and early failures that are hard to diagnose.
- Installations fail inspections, delaying handover or insurance approval.
Mistake 1: never testing the pit
A pit installed and never tested is a guess. Every pit should be tested at handover and at least yearly. Our guide on testing earth resistance explains how.
Mistake 2: burying the pit with no cover
Pits finished with soil or paved over cannot be inspected without digging, and the joint inside corrodes unseen. A proper chamber and cover cost little. See our guide on choosing a pit cover.
Mistake 3: poor joints
Twisted wires, a single loose bolt, no washers, or copper bolted straight to G.I. The joint is often the weakest point of the whole system. Use proper clamps and lugs, tighten them fully, and protect them from moisture.
Mistake 4: an undersized conductor
A thin strip or wire may test fine but can overheat or fuse during a real fault. Size the conductor for the fault current, as our guide on earthing conductors explains.
Mistake 5: a short or half-filled chemical pit
Cutting the electrode length to save cost, or filling only the bottom of the bore with compound, gives a reading well above design. Length matters more than diameter, as our guide on electrode size shows, and the bore should be filled to the specified depth.
Mistake 6: electrodes too close together
Two electrodes a metre apart behave almost like one. Space them at least as far apart as their length, and preferably more, to get the full benefit of the second electrode.
Mistake 7: an unbonded “separate” earth
A separate electrode for computers or lightning that is not bonded to the main earthing system can create dangerous voltage differences during a fault or strike. Dedicated earths are fine; isolated ones are not. Our guide on sensitive equipment explains why.
Mistake 8: forgetting the neutral
Transformer and generator neutrals need their own earthing as the regulations and design require, separate from body earthing. Our guide on DG sets and transformers covers this.
Mistake 9: choosing material by price alone
The cheapest electrode can be the most expensive one if it corrodes away in aggressive soil and has to be dug out and replaced. Our comparison of electrode materials shows how to weigh cost against service life.
Mistake 10: no records
Without a drawing showing where each pit is and what it serves, and a log of readings, nobody can spot a pit that is slowly failing. A one-page record per pit is enough.
Frequently asked questions
How can I tell if my earthing is poor?
Warning signs include tingling from metal appliances or taps, RCDs that trip often, and electronics failing after storms. The only reliable check is an earth resistance test by a qualified electrician.
Can poor earthing damage appliances?
Yes. Without a good earth, surges and faults find their way through equipment instead of into the ground, which can damage electronics and shorten the life of motors and appliances.
How often should earthing be checked?
Test at least once a year, ideally in the dry season, and after any work that might have disturbed the pits or after a lightning strike on the building.