Lightning Strike Counters: Why Recording Strikes Matters

A lightning protection system can go years without a strike, then take several in one monsoon. After a strike, clamps can loosen, conductors can be damaged and surge protectors can be used up, all without any visible sign from the ground. A lightning strike counter tells you when the system has been hit, so you know when to inspect it.

What a strike counter does

The counter is fitted on a down conductor of the lightning protection system. When a strike current flows down the conductor, the counter registers it and adds one to its display. Our digital lightning strike counter, model VE-DLSC-01, has an 8-digit display and an IP67 outdoor-rated housing.

Why it is worth fitting

  • Inspection after a strike. Guidance in IEC 62305 recommends inspecting a lightning protection system after it has been struck. Without a counter, nobody knows when that was.
  • Evidence for audits and insurance. A record of strikes supports maintenance logs and claims after storm damage.
  • Planning. A site that is struck often may justify better surge protection or a review of the design.
  • Peace of mind. It confirms that strikes are reaching the protection system rather than the structure.

Where to fit it

  • On a down conductor, above the test joint, at a height where the display can be read but not easily tampered with.
  • On the conductor most likely to carry strike current; on a large system, consider one counter on each main down conductor.
  • Fixed securely, following the maker’s instructions for clamping it around the conductor.

What to do when the count goes up

  • Note the date and new count in the maintenance log.
  • Inspect the air terminal, mast and fixings for damage.
  • Check down conductor clamps and joints for looseness or burn marks.
  • Test the earth pits, as described in our guide on testing earth resistance.
  • Check surge protection devices in the building, since many have indicators that show when they need replacing.

Part of a complete system

A counter records strikes; it does not protect anything by itself. It works alongside a properly designed air terminal, down conductors and a low-resistance earth. Our guide on ESE and conventional arresters covers the choice of terminal, and our lightning protection range includes masts, accessories and counters.

Frequently asked questions

Can a strike counter be added to an existing lightning protection system?

Yes. It is fitted on an existing down conductor, so no change to the rest of the system is needed.

Does a higher count mean the system is damaged?

Not necessarily. It means the system has been struck and has done its job. Each new strike is simply the signal to inspect the system and test the earth.

How many counters does a building need?

Small systems usually have one. On large systems with several down conductors, one on each main down conductor gives a fuller picture.

Adding a counter to an existing system is quick. Ask us for a quotation for supply or supply and fitting.


Need earthing materials or an installation quote? Send us your requirement or call +91 85788 61071.